Honeywell Flame Safeguard Controls
Honeywell Flame Safeguard (burner managment) controls are used on many different burners, including Gordon-Piatt, Cleaver-Brooks®, Industrial Combustion, Kewanee, Power Flame and Webster.
The 7800 Flame Safeguard Control Series offers a microprocessor based burner control capable of flame safety, diagnostics display, communication & networking options. Some of the more common Honeywell 7800 Series components are listed below:
7800 Series
EC7810A, EC7820A | Integrated Burner Controller |
EC7823A | Primary Flame Switch |
EC7830 EC7850 | Integrated Burner Controller (Relay Modules) |
EC7885A | Semi-Automatic Primary Control |
EC7890A,B | Primary Controls |
EC7895A,C | Full Function Primary Control |
RM7800E,G,L,M | RM7800 Programmers |
RM7823A | Primary Flame Switch |
RM7824A | Primary Control |
RM7838A,B | Semi-Automatic Industrial Primary Controls |
RM7840E,G,L,M | 7840 Programmers |
RM7885A, RM7888A | Semi-Automatic Primary Controls |
RM7890A,B,C,D | Primary Controls |
RM7895A,B,C,D,E,F | Full Function Primary Controls |
R7847, R7848, R7849 | Flame Signal Amplifiers |
R7886 | Flame Signal Amplifier |
R7B47, R7846 | Flame Detection Systems |
R7649, R7886 | Flame Dectection Systems |
Q7800A,B | 22-Terminal Universal Wiring Sub-Bases |
Q7700A,B | Network Interface Unit |
QS7800A, QS7850A | Communications Interface Control Bus Module |
ST7800A | Plug-In Purge Timer Card |
ST7810A | Data Control Bus Module TM |
S7800A | Keyboard Display Module |
S7810B | Multi-Drop Switch Module |
S7820A | Remote Reset Module |
S7830A | First Out Expanded Annunciator |
ZM7850A | Combustion System Manager TM Software |
A7800A | Tester |
CHASSIS
RM7800L-1087 | Chassis with Display |
RM7800L-1012 | Can be replaced with RM7800L-1087 |
RM7895A-1014 | Can be replaced with RM7897A-1002 |
RM7896A-1012 | Can be replaced with RM7897A-1002 |
RM7895C-1012 | Can be replaced with RM7897C-1000 |
RM7896C-1010 | Can be replaced with RM7897C-1000 |
RM7840L-1018 | Can be replaced with RM7840L-1075 |
RM7897C-1000 | RM7800 Chassis |
RM7897C-1002 | RM7800 Chassis |
RM7840L-1075 | RM7800 Chassis without Display |
SCANNERS
C554A-1463 | Cadmiun Sulfide |
C7012E-1104 | Ultraviolet (Purple Peeper) |
C7015A-1076 | Infared (Lead Sulfide) Replace with C7915A-1010 |
C7027A-1023 | Ultraviolet (Mini Peeper) |
C7915A-1010 | Infared (Lead Sulfide) |
AMPLIFIERS
R7847C-1005 | Ultlraviolet - Use with C7012E, C7012F |
R7848B-1006 | Infaredn - Use with C7015 |
R7849B-1021 | Ultraviolet - Use with C7027, C7035, C7044 |
R7849A-1023 | Ultraviolet - Use with C7027, C7035, C7044 |
PURGE TIMERS AND PURGE CARDS
ST7800A-1005 | 2 Second Purge Card |
ST7800A-1013 |
7 Second Purge Card |
ST7800A-1021 | 10 Second Purge Card |
ST7800A-1039 | 30 Second Purge Card |
ST795A-1031 | 30 Second Purge Card |
ST7800A-1054 | 60 Second Purge Card |
ST795A-1049 | 60 Second Purge Card |
ST7800-1062 | 90 Second Purge Card |
ST795A-1056 | 90 Second Purge Card |
IGNITION CONTROLS
S8610U-3009 | Ignition Control |
S87B-1016 | Ignition Control |
S87D-1012 | Ignition Control |
S8910U-1000 | Ignition Control |
SP970C-1001 | Ignition Control |
The D. B. Johnsen Company carries other Honeywell Flame Safeguard Control components and Honeywell parts such as: immersion wells, flame detectors, pressure switches, aquastats, mod motors, pilot assemblies, linkage sets, ignition modules, programmers, and relays. (See our Honeywells Controls - Aquastats, Actuators, & Valve page)
We also have limited parts for the older R4795, R7795, & R4140 series controls, however upgrading is recommended.
To request more information or to order Honeywell Flame Safeguard Controls, please call the D.B. Johnsen Company Parts Department between 8:00 AM- 4:30 PM EST at 1-800-442-1242 or click here to email us.